Impulse generator control

When the device is properly powered and has a continuous GSM connection, the high-voltage impulse generator of the electric fence can be controlled remotely via the DL Smart system.

This remote control functionality is especially useful in the following cases:

  • Service and maintenance mode – during repairs or inspection work, the high voltage can be safely switched off for an unlimited period of time.

  • Scheduled fence operation – the impulse generator can be configured to operate automatically according to a weekly schedule, with defined active and inactive time periods for each weekday.

Daily scheduled operation

Each weekday starts at 0:00 and ends at 23:59, with a one-minute time resolution.

All scheduled times are interpreted according to the time zone configured for the specific device. Please note that each DL Smart device can operate in a different time zone.

When the impulse generator control mode is set to “Schedule”, one of the following options can be defined for each weekday:

  • Impulse Generator ON – The generator operates continuously from 0:00 to 23:59.

  • Impulse Generator OFF – The generator remains switched off for the entire day, from 0:00 to 23:59.

  • Scheduled Operation – The generator operates only within or outside a defined time window.

Scheduled operation

In this mode, two time values are configured:

  • From (hour : minute)

  • Until (hour : minute)

If the “Until” time is earlier than the “From” time, the specified interval is interpreted as a non-operating (OFF) gap, and the impulse generator operates outside of this time window.

Example 1: 8:00 - 16:00 – The impulse generator will operate from 8:00 until 16:00.

Example 2: 16:00 - 8:00 – The impulse generator will operate from 0:00 until 8:00 and then from 16:00 until 23:59.

Impulse generator state changes

Any change to the impulse generator state (ON, OFF, or Schedule) is applied during the next communication cycle, which occurs approximately every 2 minutes.

If the device temporarily loses its internet connection due to missing GSM signal, the impulse generator will continue operating in the last configured state until communication with the server is restored.